Renton High School Replacement - MACC 03, Renton, WA - Specs Volume 2    

Order Prints   FastBid 3 Help  

FastBid requires JavaScript to run. Please call 425-258-1303 for more information.

This document has 1172 pages. Here are the ones with descriptions:
Click on any to load whole document, opened to the selected page.
Then use the sheet list navigation buttons to load the other pages.

Page 1 Cover Page
Page 2 Section 000107 Seals Page
Page 4 Section 000110 Table of Contents
Page 12 Section 220010 General Plumbing Provisions
Page 14 Section 220516 Expansion Fittings and Loops for Plumbing Piping
Page 16 Section 220517 Sleeves and Sleeve Seals for Plumbing Piping
Page 18 Section 220518 Escutcheons for Plumbing Piping
Page 20 Section 220519 Meters and Gages for Plumbing Piping
Page 22 Section 220523 General-Duty Valves for Plumbing Piping
Page 28 Section 220529 Hangers and Supports for Plumbing Piping and Equipment
Page 30 Section 220533 Heat Trace for Plumbing Piping
Page 32 Section 220548 Vibration and Seismic Controls for Plumbing Piping and Equipment
Page 34 Section 220553 Identification for Plumbing Piping and Equipment
Page 38 Section 220593 Testing, Adjusting, and Balancing for Plumbing
Page 40 Section 220719 Plumbing Piping Insulation
Page 44 Section 221116 Domestic Water Piping
Page 54 Section 221119 Domestic Water Piping Specialties
Page 62 Section 221123 Domestic Water Pumps
Page 66 Section 221123.13 Domestic-Water Packaged Booster Pumps
Page 70 Section 221316 Sanitary Waste and Vent Piping
Page 80 Section 221319 Sanitary Waste Piping Specialties
Page 90 Section 221413 Facility Storm Drainage Piping
Page 98 Section 221423 Storm Drainage Piping Specialties
Page 104 Section 221429 Sump Pumps
Page 108 Section 221513 General-Service Compressed-Air Piping
Page 118 Section 221519 General-Service Packaged Air Compressors and Receivers
Page 122 Section 222000 Earthwork for Underground Mechanical Systems
Page 124 Section 223300 Electric, Domestic-Water Heaters
Page 134 Section 224000 Plumbing Fixtures
Page 150 Section 226600 Chemical-Waste Systems for Laboratory and Healthcare Facilities
Page 156 Section 230010 General HVAC Provisions
Page 172 Section 230513 Common Motor Requirements for HVAC Equipment
Page 174 Section 230516 Expansion Fittings and Loops for HVAC Piping
Page 178 Section 230517 Sleeves and Seals for HVAC Piping
Page 182 Section 230518 Escutcheons for HVAC Piping
Page 184 Section 230519 Meters and Gages for HVAC Piping
Page 188 Section 230523 General-Duty Valves for HVAC Piping
Page 194 Section 230529 Hangers and Supports for HVAC Piping and Equipment
Page 204 Section 230533 Heat Tracing for HVAC Piping
Page 208 Section 230548 Vibration and Seismic Controls for HVAC
Page 220 Section 230553 Identification for HVAC Piping and Equipment
Page 224 Section 230593 Testing, Adjusting, and Balancing for HVAC
Page 242 Section 230700 HVAC Insulation
Page 262 Section 230923.1 Direct-Digital Control System for Plumbing and HVAC
Page 304 Section 230993 Sequence of Operations for HVAC Controls
Page 360 Section 231123 Natural-Gas Piping
Page 370 Section 232113 Hydronic Piping
Page 380 Section 232116 Hydronic Piping Specialties
Page 388 Section 232123 Hydronic Pumps
Page 392 Section 232300 Refrigerant Piping
Page 398 Section 233113 Metal Ducts
Page 414 Section 233300 Air Duct Accessories
Page 428 Section 233423 HVAC Power Ventilators
Page 440 Section 233600 Air Terminal Units
Page 446 Section 233713 Diffusers, Registers, and Grilles
Page 450 Section 233723 HVAC Gravity Ventilators
Page 454 Section 234100 Particulate Air Filtration
Page 458 Section 235213 Electric Boilers
Page 464 Section 236423 Scroll Air-To-Water Heat Pumps
Page 468 Section 237323 Air-Handling Units
Page 478 Section 238126 Split-System Air-Conditioners
Page 482 Section 238219 Fan Coil Units
Page 486 Section 238239 Unit Heaters
Page 492 Section 238245 Chilled Beams
Page 496 Section 260000 Electrical General Conditions
Page 508 Section 260010 Excavation and Backfill for Electrical Underground Utilities
Page 512 Section 260519 Wires and Cables
Page 516 Section 260526 Grounding
Page 520 Section 260532 Outlet and Pull Boxes
Page 524 Section 260533 Raceway
Page 528 Section 260534 Metal-Clad Cable (Type MC) and Fittings
Page 532 Section 260539 Floor Outlet Devices - Flush
Page 534 Section 260573 Electrical System Studies
Page 540 Section 260923 Network Digital Lighting Control System
Page 550 Section 260961 Theatrical Lighting Controls
Page 568 Section 260962 Theatrical Lighting Distribution Devices
Page 574 Section 260999 Production Venue Electrical Coordination
Page 576 Section 262213 Dry Type Transformers
Page 578 Section 262413 Switchboards
Page 584 Section 262416 Panelboards
Page 588 Section 262419 Motor Controllers
Page 592 Section 262726 Switches and Receptacles
Page 596 Section 262813 Fuses
Page 598 Section 262816 Disconnects and Fused Switches
Page 600 Section 263100 Photovoltaic Grid Interface System
Page 604 Section 263214 Emergency Generator
Page 614 Section 263613 3-Way Manual Transfer Switch
Page 618 Section 263623 Automatic Transfer Switches - Time Delay Neutral
Page 620 Section 264300 Surge Protective Device (SPD)
Page 628 Section 265000 Lighting
Page 634 Section 265121 Production Venue General Lighting
Page 638 Section 270000 Low Voltage General Requirements
Page 668 Section 270528 Pathways for Communications Systems
Page 676 Section 272000 Data and Voice Infrastructure
Page 700 Section 273000 Elevator Landing - Two-Way Communication System
Page 706 Section 274113 Classroom Audio-Visual System
Page 712 Section 274114 Specialty Audio-Visual Systems
Page 718 Section 274116.10 Music Room Sound System
Page 726 Section 274116.11 Commons Audio-Visual System
Page 740 Section 275113 Communication / Clock / Program System
Page 756 Section 275319 Distributed Antenna System (DAS)
Page 762 Section 281300 Access Control System
Page 778 Section 281600 Intrusion Alarm System
Page 790 Section 282300 Closed Circuit Television System (CCTV)
Page 798 Section 283176 Fire Alarm / Emergency Communication System
Page 864 Section 316329 Drilled Concrete Piers and Shafts
Page 868 Section 316613 Aggregate Pier Ground Improvements
Page 876 Appendix A Geotechnical Report
Page 982 Appendix B Limited Hazardous Materials Survey Report
Page 1136 Appendix C Archaeological Monitoring Support Requirements During Ground Disturbance Renton High School Phase 1 Construction
Page 1142 Appendix D Monitoring and Inadvertent Discovery Plan (MIDP)