Cathcart Vactor Waste Storage Facility, Snohomish County, WA #RR8761 / PW-25-0428SB
$1,057,418.50
Documents:
Notice of Call for Bids
Plans
Specs
Official Proposal to be turned in for bid opening
Addendum #1:
Addendum #1
Addendum #2:
Addendum #2
Addendum #3:
Addendum #3
Register on this project.
View self registered Bidders List
Builders Exchange of Washington, Inc. Subs and Suppliers
Owner:
Snohomish County Public Works
3000 Rockefeller Avenue
M/S 507 - 5 Admn. East, Robert J. Drewel Building
Everett, WA 98201-4067
425-388-3344
purchasing@snoco.org
Issued by:
www.bxwa.com
Prebid: Site Walk: 8/13 @ 8:00 am, & 8/26 @ 9:00 am, 8915 Cathcart Way, Snohomish, WA 98296. Parking in front of Building M
Notes:
Bid Opening Information:
https://teams.microsoft.com/dl/launcher/launcher.html?url=%2F_%23%2Fl%2Fmeetup-join%2F19%3Ameeting_M2ZmMjUyMGYtZTdiZC00ODA5LTllMTAtNjFkMTMyZGI2YjNm%40thread.v2%2F0%3Fcontext%3D%257b%2522Tid%2522%253a%25226bd456aa-bc07-4218-897c-4d0a6a503ee2%2522%252c%2522Oid%2522%253a%252248564626-32d7-479b-b123-be51617e7a05%2522%257d%26anon%3Dtrue&type=meetup-join&deeplinkId=8f325ab0-de5e-4acb-bb64-c0a0af9d38b5&directDl=true&msLaunch=true&enableMobilePage=true&suppressPrompt=true
Phone Number is 1-425-262-2000
Phone Conference ID is 712 654 577#
Description:
Vactor Waste Storage Facility Work:
1. Contractor shall construct a nominal 60 foot by 75 foot tensioned fabric structure for temporary storage of vactor waste adjacent to a similar existing structure at the Project Site.
2. The work includes the following:
a. Removal of existing asphalt paving.
b. Site grading and fill for the new facility floor slab.
c. Reinforced concrete floor slab.
d. Precast concrete block walls placed on the new floor slab.
e. Supply and erection of the tensioned fabric structure on the precast concrete block foundation walls.
f. Asphalt pavement and pavement patching.
3. Replace the fabric cover on the adjacent existing structure.
4. Obtain and pay for all permits required for the work including off-site transportation permit(s) if applicable, and any other permits.
5. Temporary facilities including but not limited to temporary utilities, Contractor’s office trailer (if needed), supplies, temporary barricades, signage, traffic management, flagging and other means of protecting the public and operations staff from hazards of the Work including traffic control during delivery and offloading of the tensioned fabric structure materials, and items in accordance with requirements of Section 01 57 19, “Temporary Facilities and Controls.”